average~ Reference

Multi-mode signal average

average~

Description

Use the average~ to perform bipolar, absolute, or rms averaging on any input signal.

Examples

Running average of a signal across n samples

Arguments

max-averaging-interval [int]

Optional
Unitssamples

Sets the maximum averaging interval in samples. The default value is 100.

averaging-mode [symbol]

Optional

Sets the averaging mode, as defined in the "Messages" section. The default is bipolar.

Attributes

mode [symbol]8.0.0

Sets the averaging mode for the input signal. Possible values:

'bipolar' ( Average input )
Sets bipolar averaging mode (default). In bipolar mode, the sample values are averaged.

'absolute' ( Average the absolute value of input )
Sets absolute averaging mode. This mode averages the absolute value of the incoming samples.

'rms' ( Root mean square input )
Sets root mean square (RMS) averaging mode. This mode computes the square root of the average of the sample values squared.

The RMS mode of the average~ object is more CPU-intensive than the bipolar and absolute modes. While RMS values are often used to measure signal levels, the absolute mode often works as well as the RMS mode in many level-detection tasks.

Common Box Attributes

annotation [symbol]

Sets the text that will be displayed in the Clue window when the user moves the mouse over the object.

background [int] (default: 0)

Adds or removes the object from the patcher's background layer. background 1 adds the object to the background layer, background 0 removes it. Objects in the background layer are shown behind all objects in the default foreground layer.

color [4 floats]

Sets the color for the object box outline.

fontface [int]

Sets the type style used by the object. The options are:

plain
bold
italic
bold italic Possible values:

0 = 'regular'
1 = 'bold'
2 = 'italic'
3 = 'bold italic'

fontname [symbol]

Sets the object's font.

fontsize [float]

Sets the object's font size (in points). Possible values:

'8'
'9'
'10'
'11'
'12'
'13'
'14'
'16'
'18'
'20'
'24'
'30'
'36'
'48'
'64'
'72'

hidden [int] (default: 0)

Toggles whether an object is hidden when the patcher is locked.

hint [symbol]

Sets the text that will be displayed in as a pop-up hint when the user moves the mouse over the object in a locked patcher.

ignoreclick [int] (default: 0)

Toggles whether an object ignores mouse clicks in a locked patcher.

jspainterfile [symbol]

JS Painter File

patching_rect [4 floats] (default: 0. 0. 100. 0.)

Sets the position and size of the object in the patcher window.

position [2 floats]

g/s(set)

Sets the object's x and y position in both patching and presentation modes (if the object belongs to its patcher's presentation), leaving its size unchanged.

presentation [int] (default: 0)

Sets whether an object belongs to the patcher's presentation.

presentation_rect [4 floats] (default: 0. 0. 0. 0.)

Sets the x and y position and width and height of the object in the patcher's presentation, leaving its patching position unchanged.

rect [4 floats]

g/s(set)

Sets the x and y position and width and height of the object in both patching and presentation modes (if the object belongs to its patcher's presentation).

size [2 floats]

g/s(set)

Sets the object's width and height in both patching and presentation modes (if the object belongs to its patcher's presentation), leaving its position unchanged.

textcolor [4 floats]

Sets the color for the object's text in RGBA format.

textjustification [int]

Sets the justification for the object's text. Possible values:

0 = 'left'
1 = 'center'
2 = 'right'

varname [symbol]

Sets the patcher's scripting name, which can be used to address the object by name in pattr, scripting messages to thispatcher, and the js object.

Messages

int

Arguments

averaging-sample-interval [int]
Sets the interval in samples used for each of the three modes of signal averaging. The default value is 100.

absolute

Sets absolute averaging mode. This mode averages the absolute value of the incoming samples.

bipolar

Sets bipolar averaging mode (default). In bipolar mode, the sample values are averaged.

rms

Sets root mean square (RMS) averaging mode. This mode computes the square root of the average of the sample values squared.

The RMS mode of the average~ object is more CPU-intensive than the bipolar and absolute modes.While RMS values are often used to measure signal levels, the absolute mode often works as well as the RMS mode in many level-detection tasks.

signal

The signal to be averaged.

Output

signal

The running average value of the input signal averaged over the specified number of samples.

See Also

Name Description
avg~ Signal average
meter~ Visual peak level indicator
MSP Compression Introduction: What is Compression? MSP Compression Introduction: What is Compression?