number~
Examples
Inlets
input [signal, number]
Input to displayramp [number]
Ramp time in milliseconds.Outlets
output [signal]
Number Value as a Signalvalue [number]
Signal ValueFixed Attributes
These attributes must be set in the object box and determine the behavior of the object at runtime.
displaymode [enum] (default: first)
Sets the monitor display mode. The default is 'first', which displays the values as in Max's number~ object (taking the first sample of the current signal buffer). 'average' displays the average value of the current signal buffer.
Possible values:0 = 'first'
1 = 'average'
initialMode [enum] (default: sig)
initialMode
Possible values:
0 = 'sig'
1 = 'monitor'
interval [number] (default: 100)
Update Interval in Milliseconds
Dynamic Attributes
These attributes can be modified in the code during execution using the set object
assign [number]
assign
input [signal, number]
Input to display
mode [number] (default: 1)
mode
monitor [list]
monitor
ramp [number]
Ramp time in milliseconds.
setup [number]
setup
See Also
Name | Description |
---|---|
number~ | Signal monitor and constant generator |
number | number box |
meter~ | Signal Meter. |